Product Description
Electrical & Mechanical Properties
Nominal Conductor Diameter |
mm |
0.32 |
0.4 |
0.5 |
0.63 |
0.9 |
Conductor Gauge Size |
AWG |
28 |
26 |
24 |
22 |
19 |
Conductor Size |
mm2 |
0.08 |
0.126 |
0.196 |
0.312 |
0.636 |
Maximum Average Conductor Resistance @20°C |
/km |
223 |
143 |
91 |
58 |
28 |
Minimum Insulation Resistance @500V DC |
M.km |
6500 |
6500 |
6500 |
6500 |
6500 |
Maximum Average Mutual Capacitance @800Hz |
nF/km |
53/68* |
53 |
53 |
56 |
59 |
Maximum Individual Mutual Capacitance @800Hz (for 99% cases) |
nF/km |
60/75* |
60 |
60 |
60 |
64 |
Maximum Individual Capacitance Unbalance @800Hz pair-to-pair |
pF/500m |
275 |
275 |
275 |
275 |
275 |
Maximum Conductor Loop Resistance @20°C |
/km |
470 |
300 |
192 |
114 |
60 |
Impedance @1KHz |
|
1000 |
994 |
796 |
660 |
445 |
Impedance @100KHz |
|
156 |
147 |
134 |
125 |
122 |
Impedance @512KHz |
|
122 |
120 |
118 |
117 |
116 |
Impedance @1MHz |
|
120 |
117 |
115 |
114 |
113 |
Maximum Average Attenuation @0.8KHz |
dB/km |
1.76 |
1.64 |
1.30 |
1.04 |
0.74 |
Maximum Average Attenuation @1KHz |
dB/km |
1.8 |
1.68 |
1.35 |
1.08 |
0.76 |
Maximum Average Attenuation @3KHz |
dB/km |
3.4 |
3.18 |
2.52 |
2.01 |
1.42 |
Maximum Average Attenuation @150KHz |
dB/km |
16.8 |
11.4 |
8.3 |
6.2 |
4.4 |
Maximum Average Attenuation @772KHz |
dB/km |
29.5 |
24.3 |
19.4 |
15.4 |
10.8 |
Maximum Average Attenuation @1000KHz |
dB/km |
33.5 |
27.1 |
21.4 |
17.5 |
12.8 |
Dielectric Strength Conductor to Conductor (3secs) |
V DC |
500 |
500 |
500 |
500 |
500 |
Nominal Insulation Thickness |
mm |
0.145/0.08** |
0.175 |
0.20 |
0.26 |
0.3 |
Nominal Insulated Conductor Diameter |
mm |
0.61/0.48** |
0.75 |
0.90 |
1.15 |
1.5 |
* Mutual capacitance values may be increased by 3% for cables with a nominal number of pairs less than 400.
The values apply to 4000 and 4800 pairs 0.32mm cable only.
Mechanical and Thermal Properties
Temperature range during operation (fixed state): -30°C - +70°C
Temperature range during installation (mobile state): -20°C - +50°C
Minimum bending radius: 10 x Overall Diameter (unarmoured cables);15 x Overall Diameter (armoured cables)
Colour Code Standard colour code is per CW 1171 given in Colour Code Chart
Dimensions And Weight Solid PE Insulated & PE Sheathed Air Core Cables to CW 1171
Detailed Photos
Packaging & Shipping
Welcome to visit our factory and get our samples.
Your inquiry will be answered within 24 hours .Wishing to be your long- term partner ,please feel free to contact me ,we will do our best for you.
Choose us, won't make you disappointed:
1.15 years manufactory experience
2.OEM/ODM available
3.Steady product quality
4.Strict quality control
5.Strictly conform to CE,ROHS,Iso9001
6.Quick delivery time(20ft,25days)