Product Description
Drop Wire Cable
Application
The cables are designed for use as connection between central offices. The cables are suitable for installation in ducts, direct burial in the ground and also for aerial installation with integral suspension strand. Jelly filled option is for subscriber's cables installed underground or along the edge of pavement. An armoured option is offered for direct burial installations. A figure-8 self support option is offered for aerial installation.
Standards
• DIN VDE 0816
Construction
Conductors
Solid annealed bare copper 0.4/0.6/0.8mm, as per class 1 of DIN VDE 0295/ BS 6360/IEC 60228
Insulation
Cellular polyethylene 2YI2 type as per VDE 0207-2
Twisted Pairs
Insulated conductors are twisted into pairs with varying lay length to minimize crosstalk
Cabling Element
Star Quads
Cable Core Assembly
4 Cores are twisted into star quad. 5 star quads are stranded into a basic unit. 5 or 10 basic units each are stranded into one main unit. The star quads are grouped in units and stranded in layers to form the cable core.Standard make up is per VDE 0816 in the Cable Make Up Diagram
Core Wrapping
One or more non-hygroscopic polyester tapes are helically or longitudinally laid with an overlap. These tapes furnish thermal, mechanical as well as high dielectric protection between shielding and individual conductors
Moisture Barrier
A layer of aluminium tape (0.2mm) coated with PE-copolymer on one or both sides is applied longitudinally with overlap over the cable core to provide 100% electrical shielding coverage and ensures a barrier against water vapor
Sheath
Black low or medium density polyethylene 2YM2 type as per VDE 0207-3, being able to withstand exposure to
sunlight, temperature variations, ground chemicals and other environmental contaminants
Ripcord
Ripcord may be provided for slitting the sheath longitudinally to facilitate its removal
Spare Pairs (optional)
Spare pairs may be provided for large pair cables
Continuity Wire (optional)
Tinned copper drain wire may be longitudinally laid to ensure electrical continuity of the screen
Optional Construction
Jelly Filled Cable
The cable core interstices are filled with petroleum jelly to avoid longitudinal water penetration within the cable. The water resistant filling compound is applied to the air space between non-hygroscopic tape and shield,shield and sheath within the cable core
Armoured Cable
Corrugated steel tape armour is applied over an optional inner polyethylene sheath with an overlap. An outer polyethylene sheath is applied over the armour
Type Code
A- |
Outdoor Cable |
02Y |
Cellular Polyethylene (FOAM PE) insulation |
F |
Continuous core filling |
(L)2Y |
Laminated sheath(copolymer-coated aluminium tape laminated to PE outer sheath) |
SR |
Corrugated steel tape |
b |
Armouring |
T |
Messenger of galvanized steel wires |
StIII |
Star quad in local cables |
Bd |
Unit-type stranding |
Electrical Properties
Nominal Conductor Diameter |
mm |
0.4 |
0.6 |
0.8 |
Conductor Gauge Size |
AWG |
26 |
- |
20 |
Conductor Size |
mm2 |
0.126 |
0.283 |
0.5 |
Maximum Average Conductor Resistance @20°C |
/km |
143 |
63 |
34.6 |
Minimum Insulation Resistance @500V DC |
M.km |
5000 |
5000 |
5000 |
Maximum Mutual Capacitance @800Hz 95% of all values |
nF/km |
40 |
40 |
40 |
100% of all values |
nF/km |
42 |
42 |
42 |
Capacitance Unbalance @800Hz pair-to-pair |
|
|
|
|
K1 100% of values max |
pF/500m |
980 |
800 |
800 |
98% of values max |
pF/500m |
420 |
400 |
400 |
K9-12 100% of values max |
pF/500m |
800 |
300 |
300 |
90% of values max |
pF/500m |
200 |
100 |
100 |
Maximum Conductor Loop Resistance @20°C |
/km |
300 |
130 |
73.2 |
Impedance @0.8KHz |
|
994 |
665 |
500 |
Maximum Average Attenuation @0.8KHz |
dB/km |
1.45 |
0.91 |
0.68 |
Dielectric Strength 50Hz |
|
|
|
|
Conductor to Conductor (2mins) |
V AC |
500 |
500 |
500 |
Conductor to Screen (2mins) |
V AC |
2000 |
2000 |
2000 |
Maximum Operating Voltage Peak Value |
V |
150 |
225 |
225 |
Nominal Insulation Thickness (Air Core) |
mm |
0.20 |
0.25 |
0.3 |
(Jelly Filled) |
mm |
0.26 |
0.36 |
0.44 |
Nominal Insulated Conductor Diameter (Air Core) |
mm |
0.8 |
1.1 |
1.4 |
(Jelly Filled) |
mm |
0.92 |
1.32 |
1.68 |
Detailed Photos
Packaging & Shipping
Choose us, won't make you disappointed:
1.15 years manufactory experience
2.OEM/ODM available
3.Steady product quality
4.Strict quality control
5.Strictly conform to CE,ROHS,Iso9001
6.Quick delivery time(20ft,25days)