• Outdoor Self-Supporting 2 Core Drop Wire Telephone Cable
  • Outdoor Self-Supporting 2 Core Drop Wire Telephone Cable
  • Outdoor Self-Supporting 2 Core Drop Wire Telephone Cable
  • Outdoor Self-Supporting 2 Core Drop Wire Telephone Cable
  • Outdoor Self-Supporting 2 Core Drop Wire Telephone Cable
  • Outdoor Self-Supporting 2 Core Drop Wire Telephone Cable

Outdoor Self-Supporting 2 Core Drop Wire Telephone Cable

Type: Cat3
Conductor Type: Solid
Application: Overhead, Heating, Long Distance Symmetric Cable
Samples:
US$ 1/Piece 1 Piece(Min.Order)
| Order Sample
1~5m/roll, random color,1roll/box
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Outdoor Self-Supporting 2 Core Drop Wire Telephone Cable pictures & photos
Outdoor Self-Supporting 2 Core Drop Wire Telephone Cable
US $8-15 / Roll
Min. Order: 100 Rolls
Gold Member Since 2017

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Company Profile
  • Our Advantages
  • FAQ
Overview

Basic Info.

Model NO.
Drop Wire VDSL Telephone cable
Conductor Material
Copper
Sheath Material
PE
Insulation Material
PE
Material Shape
Round Wire
Range of Application
Cold-Resistant
Certification
ISO9001, CE, RoHS
Brand
Hanli
Model No
Drop Wire VDSL Telephone Cable
Wire Core Material
Bare Copper Wire
Messenger
Steel Wire 1.0*1
Color
Customized
Transport Package
305/1000m
Specification
24awg
Trademark
HANLI
Origin
Zhejiang
HS Code
8544491100
Production Capacity
2000000m/Month

Packaging & Delivery

Package Size
30.00cm * 30.00cm * 30.00cm
Package Gross Weight
15.000kg

Product Description

Product Description

Product Description
Fig8 Drop wire Idsl telephone cable

Application
   The cables are designed for using as connection between central offices. The cables are suitable for installation in ducts, direct burial in the ground and also for aerial installation with integral suspension strand. Jelly filled option is for subscriber's cables installed underground or along the edge of pavement. An armoured option is offered for direct burial installations. A figure-8 self support option is offered for aerial installation.

Standards
• DIN VDE 0816

Construction
Conductors
Solid annealed bare copper 0.4/0.6/0.8mm, as per class 1 of DIN VDE 0295/ BS 6360/IEC 60228
Insulation
Cellular polyethylene 2YI2 type as per VDE 0207-2
Twisted Pairs
Insulated conductors are twisted into pairs with varying lay length to minimize crosstalk
Cabling Element
Cable Core Assembly
4 Cores are twisted into star quad.
5 star quads are stranded into a basic unit.
5 or 10 basic units each are stranded into one main unit.
The star quads are grouped in units and stranded in layers to form the cable core.
Standard make up is per VDE 0816 in the Cable Make Up Diagram Core Wrapping
One or more non-hygroscopic polyester tapes are helically or longitudinally laid with an overlap.
These tapes furnish thermal, mechanical as well as high dielectric protection between shielding and individual conductors

Moisture Barrier
A layer of aluminium tape (0.2mm) coated with PE-copolymer on one or both sides is applied longitudinally with overlap over the cable core to provide 100% electrical shielding coverage and ensures a barrier against water vapor

Sheath
Black low or medium density polyethylene 2YM2 type as per VDE 0207-3, being able to withstand exposure to
sunlight, temperature variations, ground chemicals and other environmental contaminants

Ripcord
Ripcord may be provided for slitting the sheath longitudinally to facilitate its removal
Spare Pairs (optional)
Spare pairs may be provided for large pair cables
Continuity Wire (optional)
Tinned copper drain wire may be longitudinally laid to ensure electrical continuity of the screen
Optional Construction
Jelly Filled Cable
The cable core interstices are filled with petroleum jelly to avoid longitudinal water penetration within the cable. The water resistant filling compound is applied to the air space between non-hygroscopic tape and shield,shield and sheath within the cable core

Type Code
A- Outdoor Cable
02Y Cellular Polyethylene (FOAM PE) insulation
Continuous core filling
(L)2Y  Laminated sheath(copolymer-coated aluminium tape laminated to PE outer sheath)
SR  Corrugated steel tape
b Armouring
Messenger of galvanized steel wires
StIII Star quad in local cables
Bd  Unit-type stranding
Product Parameters

Electrical Properties

 
Nominal Conductor Diameter mm 0.4 0.6 0.8
Conductor Gauge Size AWG 26 - 20
Conductor Size mm2 0.126 0.283 0.5
Maximum Average Conductor Resistance @20°C /km 143 63 34.6
Minimum Insulation Resistance @500V DC M.km 5000 5000 5000
Maximum Mutual Capacitance @800Hz 95% of all values nF/km 40 40 40
                                                              100% of all values nF/km 42 42 42
Capacitance Unbalance @800Hz pair-to-pair        
         K1          100% of values max pF/500m 980 800 800
                        98% of values  max pF/500m 420 400 400
         K9-12    100% of values max pF/500m 800 300 300
                        90% of values  max pF/500m 200 100 100
Maximum Conductor Loop Resistance @20°C /km 300 130 73.2
Impedance @0.8KHz   994 665 500
Maximum Average Attenuation @0.8KHz dB/km 1.45 0.91 0.68
Dielectric Strength 50Hz        
         Conductor to Conductor (2mins) V AC 500 500 500
         Conductor to Screen (2mins) V AC 2000 2000 2000
Maximum Operating Voltage Peak Value V 150 225 225
Nominal Insulation Thickness (Air Core) mm 0.20 0.25 0.3
                                                  (Jelly Filled) mm 0.26 0.36 0.44
Nominal Insulated Conductor Diameter (Air Core) mm 0.8 1.1 1.4
                                                                (Jelly Filled) mm 0.92 1.32 1.68
Temperature range during operation (fixed state): -30°C - +70°C
Temperature range during installation (mobile state): -20°C - +50°C 
Minimum bending radius: 10 x Overall Diameter
Detailed Photos

Outdoor Self-Supporting 2 Core Drop Wire Telephone Cable
Outdoor Self-Supporting 2 Core Drop Wire Telephone CableOutdoor Self-Supporting 2 Core Drop Wire Telephone Cable
 

Company Profile

Outdoor Self-Supporting 2 Core Drop Wire Telephone Cable

Outdoor Self-Supporting 2 Core Drop Wire Telephone Cable
Our Advantages

Welcome to visit our factory and  get our samples.

  Your inquiry will be answered within 24 hours .Wishing to be your long- term partner ,please feel free to contact me ,we will do our best for you. 
 
Choose us, won't make you disappointed:
1.6years manufactory experience 
2.OEM/ODM available
3.Steady product quality
4.Strict quality control
5.Strictly conform to CE,ROHS,Iso9001
6.Quick delivery time(20ft,25days)
  
FAQ

1.Can I have some samples for testing quality?
A1.Yes, you can buy some samples of any our products for testing quality and market.
2.What is delivery time if we place order?
A2. It depends on order quanities. Usually,we can deliver goods within 15 days for small order. For more QTY, Let's confirm when you place official order.
3.Do you accept OEM/ODM?
A3. We support OEM/ODM service.pls don't hesitate to tell us your details.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Outdoor Self-Supporting 2 Core Drop Wire Telephone Cable pictures & photos
Outdoor Self-Supporting 2 Core Drop Wire Telephone Cable
US $8-15 / Roll
Min. Order: 100 Rolls
Gold Member Since 2017

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
Management System Certification
ISO9001:2015
OEM/ODM Availability
Yes